Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 10899mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-11-05 15:00:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-11-05 14:30:02 14:30:02 Initialize Modem [11525mV] 14:30:10 +CEREG: 2 14:30:10 +KSUP: 0 14:30:10 +CEREG: 0 14:30:10 +CEREG: 2 14:30:12 +CEREG: 5,"8002","08D9CA0C",7 14:30:12 Matched '+CEREG: 5,*' 14:30:13 AT+KPATTERN="SOLAR" 14:30:13 Charger State = 0100 [CHARGER_STATE_CHARGER_SUSPENDED] 14:30:13 Charge Status = 00d [CHARGE_STATUS_OFF] 14:30:13 Charge State Alerts = 0000 14:30:13 Charge Status Alerts = 00 14:30:13 System Status Alerts = 023 14:30:13 Unloaded Charger State = 256 [CHARGER_STATE_CHARGER_SUSPENDED] 14:30:13 Unloaded Charge Status = 0 [CHARGE_STATUS_OFF] 14:30:13 Unloaded Battery Voltage = 11968mV 14:30:14 Unloaded Input Voltage = 11289mV 14:30:14 Unloaded Output Voltage = 11957mV 14:30:14 Unloaded Battery Current = 0mA 14:30:14 Unloaded Input Current = 1mA 14:30:14 BSR = 0mOhm 14:30:14 TC ChargeTimer = 0 14:30:14 TC VTimer = 0 14:30:14 Battery Voltage = 11938mV 14:30:14 Input Voltage = 11966mV 14:30:14 Output Voltage = 11453mV 14:30:14 Battery Current = -85mA 14:30:15 Input Current = 7mA 14:30:15 Die Temp = 422 x10 DegC 14:30:15 Thermistor Voltage = 9027 14:30:15 nRF Die Temp = 352 x10 DegC 14:30:15 OK 14:30:15 Matched 'OK' 14:30:15 AT+COPS? 14:30:15 +COPS: 0,0,"Hologram",7 14:30:15 OK 14:30:15 Matched 'OK' 14:30:15 AT+CESQ 14:30:16 +CESQ: 99,99,255,255,3,34 14:30:16 OK 14:30:16 Matched 'OK' 14:30:16 AT+KBND? 14:30:16 +KBND: 0,00000000000008000000 14:30:16 OK 14:30:16 Matched 'OK' 14:30:16 Connect [10952mV] 14:30:16 ATS0=0 14:30:16 OK 14:30:16 Matched 'OK' 14:30:17 ATD*99***1# 14:30:17 CONNECT 14:30:17 Matched 'CONNECT*' 14:30:17 Connected [10974mV] 14:30:17 001 Initializing Interface: [Connect Init] 14:30:17 Initialise TCP/IP Stack 14:30:17 001 Initializing Interface: [Start PPP] 14:30:17 Connecting 14:30:20 001 Initializing Interface: [PPP Connected] 14:30:20 Connected 10.170.119.223 14:30:20 002 Initializing FTP: [Resolve Server] 14:30:20 DNS Lookup ftp.enviroscanplus.com 14:30:22 002 Initializing FTP: [Connect Server] 14:30:22 Open Connection to ftp.enviroscanplus.com 14:30:24 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 14:30:25 331 User modemtesting@enviroscanplus.com OK. Password required 14:30:27 230 OK. Current restricted directory is / 14:30:28 002 Initializing FTP: [CWD] 14:30:28 250 OK. Current directory is /HL7800 14:30:32 002 Initializing FTP: [SET Binary Mode] 14:30:32 200 TYPE is now 8-bit binary 14:30:32 003 Transferring 14:30:33 004 Uploading to Server 14:30:35 004 Uploading to Server: [Upload File] 14:30:35 227 Entering Passive Mode (198,38,77,48,197,172) 14:30:44 001 Initializing Interface 14:31:43 Disconnect 14:31:47 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&KI}+é}'}"}(}"à¿~~ÿ}#À!}%}#} }0User requesty{~ 14:31:47 NO CARRIER 14:31:47 Matched 'NO CARRIER' 14:31:47 AT+CESQ 14:31:47 +CESQ: 99,99,255,255,0,32 14:31:47 OK 14:31:47 Matched 'OK' 14:31:47 AT+CPWROFF 14:31:52 +CEREG: 4 14:31:53 +CEREG: 0 14:31:53 OK 14:31:53 Matched 'OK' 14:32:02 Error timeout 14:32:02 Power down [11029mV]