Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 10942mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-11-05 14:45:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-11-05 14:15:02 14:15:02 Initialize Modem [11624mV] 14:15:10 +CEREG: 2 14:15:10 +KSUP: 0 14:15:10 +CEREG: 0 14:15:10 +CEREG: 2 14:15:12 +CEREG: 5,"8002","08D9CA0C",7 14:15:12 Matched '+CEREG: 5,*' 14:15:13 AT+KPATTERN="SOLAR" 14:15:13 Charger State = 0800 [CHARGER_STATE_CHARGER_SUSPENDED] 14:15:13 Charge Status = 00d [CHARGE_STATUS_OFF] 14:15:13 Charge State Alerts = 0000 14:15:13 Charge Status Alerts = 00 14:15:13 System Status Alerts = 023 14:15:13 Unloaded Charger State = 2048 [CHARGER_STATE_CHARGER_SUSPENDED] 14:15:13 Unloaded Charge Status = 0 [CHARGE_STATUS_OFF] 14:15:14 Unloaded Battery Voltage = 11973mV 14:15:14 Unloaded Input Voltage = 11330mV 14:15:14 Unloaded Output Voltage = 11966mV 14:15:14 Unloaded Battery Current = 0mA 14:15:14 Unloaded Input Current = 2mA 14:15:14 BSR = 0mOhm 14:15:14 TC ChargeTimer = 0 14:15:14 TC VTimer = 0 14:15:14 Battery Voltage = 11930mV 14:15:14 Input Voltage = 11973mV 14:15:14 Output Voltage = 11465mV 14:15:15 Battery Current = 0mA 14:15:15 Input Current = 7mA 14:15:15 Die Temp = 416 x10 DegC 14:15:15 Thermistor Voltage = 9104 14:15:15 nRF Die Temp = 357 x10 DegC 14:15:15 OK 14:15:15 Matched 'OK' 14:15:15 AT+COPS? 14:15:15 +COPS: 0,0,"Hologram",7 14:15:15 OK 14:15:15 Matched 'OK' 14:15:16 AT+CESQ 14:15:16 +CESQ: 99,99,255,255,0,32 14:15:16 OK 14:15:16 Matched 'OK' 14:15:16 AT+KBND? 14:15:16 +KBND: 0,00000000000008000000 14:15:16 OK 14:15:16 Matched 'OK' 14:15:16 Connect [10980mV] 14:15:16 ATS0=0 14:15:16 OK 14:15:16 Matched 'OK' 14:15:17 ATD*99***1# 14:15:17 CONNECT 14:15:17 Matched 'CONNECT*' 14:15:17 Connected [10915mV] 14:15:17 001 Initializing Interface: [Connect Init] 14:15:17 Initialise TCP/IP Stack 14:15:17 001 Initializing Interface: [Start PPP] 14:15:17 Connecting 14:15:20 001 Initializing Interface: [PPP Connected] 14:15:20 Connected 10.170.119.223 14:15:20 002 Initializing FTP: [Resolve Server] 14:15:20 DNS Lookup ftp.enviroscanplus.com 14:15:22 002 Initializing FTP: [Connect Server] 14:15:22 Open Connection to ftp.enviroscanplus.com 14:15:25 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 14:15:26 331 User modemtesting@enviroscanplus.com OK. Password required 14:15:48 230 OK. Current restricted directory is / 14:15:49 002 Initializing FTP: [CWD] 14:15:49 250 OK. Current directory is /HL7800 14:15:49 002 Initializing FTP: [SET Binary Mode] 14:15:49 200 TYPE is now 8-bit binary 14:15:50 003 Transferring 14:15:50 004 Uploading to Server 14:15:54 004 Uploading to Server: [Upload File] 14:15:54 227 Entering Passive Mode (198,38,77,48,202,28) 14:16:01 001 Initializing Interface 14:17:42 Disconnect 14:17:46 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&pVë”}'}"}(}"­²~~ÿ}#À!}%}#} }0User requesty{~ 14:17:46 NO CARRIER 14:17:46 Matched 'NO CARRIER' 14:17:46 AT+CESQ 14:17:46 +CESQ: 99,99,255,255,0,38 14:17:46 OK 14:17:46 Matched 'OK' 14:17:46 AT+CPWROFF 14:17:46 +CEREG: 0 14:17:46 +CEREG: 0 14:17:46 OK 14:17:46 Matched 'OK' 14:17:55 Error timeout 14:17:55 Power down [10964mV]