Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 10930mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-11-05 13:45:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-11-05 13:15:02 13:15:02 Initialize Modem [11515mV] 13:15:10 +CEREG: 2 13:15:10 +KSUP: 0 13:15:10 +CEREG: 0 13:15:10 +CEREG: 2 13:15:12 +CEREG: 5,"8003","08D9BF0D",7 13:15:12 Matched '+CEREG: 5,*' 13:15:12 AT+KPATTERN="SOLAR" 13:15:12 Charger State = 0100 [CHARGER_STATE_CHARGER_SUSPENDED] 13:15:13 Charge Status = 00d [CHARGE_STATUS_OFF] 13:15:13 Charge State Alerts = 0000 13:15:13 Charge Status Alerts = 00 13:15:13 System Status Alerts = 067 13:15:13 Unloaded Charger State = 256 [CHARGER_STATE_CHARGER_SUSPENDED] 13:15:13 Unloaded Charge Status = 0 [CHARGE_STATUS_OFF] 13:15:13 Unloaded Battery Voltage = 11971mV 13:15:13 Unloaded Input Voltage = 11453mV 13:15:13 Unloaded Output Voltage = 11966mV 13:15:13 Unloaded Battery Current = 0mA 13:15:14 Unloaded Input Current = 1mA 13:15:14 BSR = 0mOhm 13:15:14 TC ChargeTimer = 0 13:15:14 TC VTimer = 0 13:15:14 Battery Voltage = 11953mV 13:15:14 Input Voltage = 11978mV 13:15:14 Output Voltage = 11445mV 13:15:14 Battery Current = 0mA 13:15:14 Input Current = 7mA 13:15:14 Die Temp = 379 x10 DegC 13:15:15 Thermistor Voltage = 9865 13:15:15 nRF Die Temp = 302 x10 DegC 13:15:15 OK 13:15:15 Matched 'OK' 13:15:15 AT+COPS? 13:15:15 +COPS: 0,0,"Hologram",7 13:15:15 OK 13:15:15 Matched 'OK' 13:15:15 AT+CESQ 13:15:15 +CESQ: 99,99,255,255,15,46 13:15:15 OK 13:15:15 Matched 'OK' 13:15:16 AT+KBND? 13:15:16 +KBND: 0,00000000000008000000 13:15:16 OK 13:15:16 Matched 'OK' 13:15:16 Connect [10988mV] 13:15:16 ATS0=0 13:15:16 OK 13:15:16 Matched 'OK' 13:15:16 ATD*99***1# 13:15:16 CONNECT 13:15:16 Matched 'CONNECT*' 13:15:17 Connected [10946mV] 13:15:17 001 Initializing Interface: [Connect Init] 13:15:17 Initialise TCP/IP Stack 13:15:17 001 Initializing Interface: [Start PPP] 13:15:17 Connecting 13:15:20 001 Initializing Interface: [PPP Connected] 13:15:20 Connected 10.170.119.223 13:15:20 002 Initializing FTP: [Resolve Server] 13:15:20 DNS Lookup ftp.enviroscanplus.com 13:15:21 002 Initializing FTP: [Connect Server] 13:15:21 Open Connection to ftp.enviroscanplus.com 13:15:22 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 13:15:23 331 User modemtesting@enviroscanplus.com OK. Password required 13:15:24 230 OK. Current restricted directory is / 13:15:25 002 Initializing FTP: [CWD] 13:15:25 250 OK. Current directory is /HL7800 13:15:25 002 Initializing FTP: [SET Binary Mode] 13:15:25 200 TYPE is now 8-bit binary 13:15:26 003 Transferring 13:15:26 004 Uploading to Server 13:15:27 004 Uploading to Server: [Upload File] 13:15:27 227 Entering Passive Mode (198,38,77,48,202,153) 13:15:30 001 Initializing Interface 13:15:40 Disconnect 13:15:44 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&Jyæ£}'}"}(}"SÒ~~ÿ}#À!}%}#} }0User requesty{~ 13:15:44 NO CARRIER 13:15:44 Matched 'NO CARRIER' 13:15:44 AT+CESQ 13:15:44 +CESQ: 99,99,255,255,18,50 13:15:44 OK 13:15:44 Matched 'OK' 13:15:44 AT+CPWROFF 13:15:45 +CEREG: 0 13:15:45 +CEREG: 0 13:15:45 OK 13:15:45 Matched 'OK' 13:15:54 Error timeout 13:15:54 Power down [10938mV]