Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 11464mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-11-05 10:45:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-11-05 10:15:02 10:15:02 Initialize Modem [11513mV] 10:15:10 +CEREG: 2 10:15:10 +KSUP: 0 10:15:10 +CEREG: 0 10:15:10 +CEREG: 2 10:15:11 +CEREG: 5,"8003","08D9BF0D",7 10:15:11 Matched '+CEREG: 5,*' 10:15:11 AT+KPATTERN="SOLAR" 10:15:12 Charger State = 0100 [CHARGER_STATE_CHARGER_SUSPENDED] 10:15:12 Charge Status = 00d [CHARGE_STATUS_OFF] 10:15:12 Charge State Alerts = 0000 10:15:12 Charge Status Alerts = 00 10:15:12 System Status Alerts = 023 10:15:12 Unloaded Charger State = 256 [CHARGER_STATE_CHARGER_SUSPENDED] 10:15:12 Unloaded Charge Status = 0 [CHARGE_STATUS_OFF] 10:15:12 Unloaded Battery Voltage = 11993mV 10:15:12 Unloaded Input Voltage = 11976mV 10:15:12 Unloaded Output Voltage = 12014mV 10:15:13 Unloaded Battery Current = 0mA 10:15:13 Unloaded Input Current = 1mA 10:15:13 BSR = 0mOhm 10:15:13 TC ChargeTimer = 0 10:15:13 TC VTimer = 0 10:15:13 Battery Voltage = 11969mV 10:15:13 Input Voltage = 11876mV 10:15:13 Output Voltage = 11977mV 10:15:13 Battery Current = 0mA 10:15:13 Input Current = 1mA 10:15:13 Die Temp = 238 x10 DegC 10:15:14 Thermistor Voltage = 12138 10:15:14 nRF Die Temp = 152 x10 DegC 10:15:14 OK 10:15:14 Matched 'OK' 10:15:14 AT+COPS? 10:15:14 +COPS: 0,0,"Hologram",7 10:15:14 OK 10:15:14 Matched 'OK' 10:15:14 AT+CESQ 10:15:14 +CESQ: 99,99,255,255,9,43 10:15:14 OK 10:15:14 Matched 'OK' 10:15:15 AT+KBND? 10:15:15 +KBND: 0,00000000000008000000 10:15:15 OK 10:15:15 Matched 'OK' 10:15:15 Connect [11419mV] 10:15:15 ATS0=0 10:15:15 OK 10:15:15 Matched 'OK' 10:15:15 ATD*99***1# 10:15:15 CONNECT 10:15:15 Matched 'CONNECT*' 10:15:16 Connected [11436mV] 10:15:16 001 Initializing Interface: [Connect Init] 10:15:16 Initialise TCP/IP Stack 10:15:16 001 Initializing Interface: [Start PPP] 10:15:16 Connecting 10:15:19 001 Initializing Interface: [PPP Connected] 10:15:19 Connected 10.170.119.223 10:15:19 002 Initializing FTP: [Resolve Server] 10:15:19 DNS Lookup ftp.enviroscanplus.com 10:15:20 002 Initializing FTP: [Connect Server] 10:15:20 Open Connection to ftp.enviroscanplus.com 10:15:22 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 10:15:22 331 User modemtesting@enviroscanplus.com OK. Password required 10:15:23 230 OK. Current restricted directory is / 10:15:24 002 Initializing FTP: [CWD] 10:15:24 250 OK. Current directory is /HL7800 10:15:24 002 Initializing FTP: [SET Binary Mode] 10:15:24 200 TYPE is now 8-bit binary 10:15:25 003 Transferring 10:15:25 004 Uploading to Server 10:15:26 004 Uploading to Server: [Upload File] 10:15:26 227 Entering Passive Mode (198,38,77,48,199,152) 10:15:29 001 Initializing Interface 10:15:40 Disconnect 10:15:44 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&+Y*õ}'}"}(}"}3›~~ÿ}#À!}%}#} }0User requesty{~ 10:15:44 NO CARRIER 10:15:44 Matched 'NO CARRIER' 10:15:44 AT+CESQ 10:15:44 +CESQ: 99,99,255,255,9,47 10:15:44 OK 10:15:44 Matched 'OK' 10:15:44 AT+CPWROFF 10:15:44 +CEREG: 0 10:15:45 +CEREG: 0 10:15:45 OK 10:15:45 Matched 'OK' 10:15:54 Error timeout 10:15:54 Power down [11430mV]