Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 14239mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-11-04 07:15:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-11-04 06:45:02 06:45:02 Initialize Modem [14316mV] 06:45:10 +CEREG: 2 06:45:11 +CEREG: 0 06:45:11 +CEREG: 2 06:45:11 +KSUP: 0 06:45:12 +CEREG: 5,"8010","08DAE50C",7 06:45:12 Matched '+CEREG: 5,*' 06:45:13 AT+KPATTERN="SOLAR" 06:45:13 Charger State = 0040 [CHARGER_STATE_CC_CV_CHARGE] 06:45:13 Charge Status = 04d [CHARGE_STATUS_IIN_LIMIT_ACTIVE] 06:45:13 Charge State Alerts = 0000 06:45:14 Charge Status Alerts = 00 06:45:14 System Status Alerts = 147 06:45:14 Unloaded Charger State = 64 [CHARGER_STATE_CC_CV_CHARGE] 06:45:14 Unloaded Charge Status = 4 [CHARGE_STATUS_IIN_LIMIT_ACTIVE] 06:45:14 Unloaded Battery Voltage = 11942mV 06:45:14 Unloaded Input Voltage = 14662mV 06:45:14 Unloaded Output Voltage = 14681mV 06:45:14 Unloaded Battery Current = 195mA 06:45:14 Unloaded Input Current = 190mA 06:45:14 BSR = 0mOhm 06:45:15 TC ChargeTimer = 0 06:45:15 TC VTimer = 0 06:45:15 Battery Voltage = 11924mV 06:45:15 Input Voltage = 14661mV 06:45:15 Output Voltage = 14681mV 06:45:15 Battery Current = 156mA 06:45:15 Input Current = 190mA 06:45:15 Die Temp = 351 x10 DegC 06:45:15 Thermistor Voltage = 10468 06:45:15 nRF Die Temp = 205 x10 DegC 06:45:15 OK 06:45:15 Matched 'OK' 06:45:16 AT+COPS? 06:45:16 +COPS: 0,0,"Hologram",7 06:45:16 OK 06:45:16 Matched 'OK' 06:45:16 AT+CESQ 06:45:16 +CESQ: 99,99,255,255,19,50 06:45:16 OK 06:45:16 Matched 'OK' 06:45:16 AT+KBND? 06:45:16 +KBND: 0,00000000000008000000 06:45:16 OK 06:45:16 Matched 'OK' 06:45:17 Connect [14233mV] 06:45:17 AT+CCLK? 06:45:17 +CCLK: "19/11/04,06:45:16+42" 06:45:17 OK 06:45:17 Matched 'OK' 06:45:17 ATS0=0 06:45:17 OK 06:45:17 Matched 'OK' 06:45:17 ATD*99***1# 06:45:17 CONNECT 06:45:17 Matched 'CONNECT*' 06:45:18 Connected [14277mV] 06:45:18 001 Initializing Interface: [Connect Init] 06:45:18 Initialise TCP/IP Stack 06:45:18 001 Initializing Interface: [Start PPP] 06:45:18 Connecting 06:45:21 001 Initializing Interface: [PPP Connected] 06:45:21 Connected 10.170.119.223 06:45:21 002 Initializing FTP: [Resolve Server] 06:45:21 DNS Lookup ftp.enviroscanplus.com 06:45:22 002 Initializing FTP: [Connect Server] 06:45:22 Open Connection to ftp.enviroscanplus.com 06:45:24 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 06:45:25 331 User modemtesting@enviroscanplus.com OK. Password required 06:45:26 230 OK. Current restricted directory is / 06:45:27 002 Initializing FTP: [CWD] 06:45:27 250 OK. Current directory is /HL7800 06:45:28 002 Initializing FTP: [SET Binary Mode] 06:45:28 200 TYPE is now 8-bit binary 06:45:28 003 Transferring 06:45:28 004 Uploading to Server 06:45:29 004 Uploading to Server: [Upload File] 06:45:29 227 Entering Passive Mode (198,38,77,48,195,178) 06:45:33 001 Initializing Interface 06:45:45 Disconnect 06:45:49 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&f}9·ñ}'}"}(}"äÜ~~ÿ}#À!}%}#} }0User requesty{~ 06:45:49 NO CARRIER 06:45:49 Matched 'NO CARRIER' 06:45:49 AT+CESQ 06:45:49 +CESQ: 99,99,255,255,20,49 06:45:49 OK 06:45:49 Matched 'OK' 06:45:49 AT+CPWROFF 06:45:49 +CEREG: 0 06:45:49 +CEREG: 0 06:45:49 OK 06:45:49 Matched 'OK' 06:45:58 Error timeout 06:45:58 Power down [14253mV]