Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 14289mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-11-04 04:15:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-11-04 03:45:02 03:45:02 Initialize Modem [14336mV] 03:45:09 +KSUP: 0 03:45:10 +CEREG: 2 03:45:10 +CEREG: 0 03:45:10 +CEREG: 2 03:45:11 +CEREG: 5,"8010","08DAE50C",7 03:45:11 Matched '+CEREG: 5,*' 03:45:13 AT+KPATTERN="SOLAR" 03:45:13 Charger State = 0040 [CHARGER_STATE_CC_CV_CHARGE] 03:45:13 Charge Status = 04d [CHARGE_STATUS_IIN_LIMIT_ACTIVE] 03:45:13 Charge State Alerts = 0000 03:45:13 Charge Status Alerts = 00 03:45:13 System Status Alerts = 147 03:45:13 Unloaded Charger State = 64 [CHARGER_STATE_CC_CV_CHARGE] 03:45:13 Unloaded Charge Status = 4 [CHARGE_STATUS_IIN_LIMIT_ACTIVE] 03:45:13 Unloaded Battery Voltage = 11476mV 03:45:13 Unloaded Input Voltage = 14659mV 03:45:14 Unloaded Output Voltage = 14676mV 03:45:14 Unloaded Battery Current = 202mA 03:45:14 Unloaded Input Current = 190mA 03:45:14 BSR = 0mOhm 03:45:14 TC ChargeTimer = 0 03:45:14 TC VTimer = 0 03:45:14 Battery Voltage = 11449mV 03:45:14 Input Voltage = 14659mV 03:45:14 Output Voltage = 14676mV 03:45:14 Battery Current = 126mA 03:45:15 Input Current = 190mA 03:45:15 Die Temp = 369 x10 DegC 03:45:15 Thermistor Voltage = 10227 03:45:15 nRF Die Temp = 215 x10 DegC 03:45:15 OK 03:45:15 Matched 'OK' 03:45:15 AT+COPS? 03:45:15 +COPS: 0,0,"Hologram",7 03:45:15 OK 03:45:15 Matched 'OK' 03:45:15 AT+CESQ 03:45:15 +CESQ: 99,99,255,255,23,50 03:45:16 OK 03:45:16 Matched 'OK' 03:45:16 AT+KBND? 03:45:16 +KBND: 0,00000000000008000000 03:45:16 OK 03:45:16 Matched 'OK' 03:45:16 Connect [14237mV] 03:45:16 AT+CCLK? 03:45:16 +CCLK: "19/11/04,03:45:15+42" 03:45:16 OK 03:45:16 Matched 'OK' 03:45:17 ATS0=0 03:45:17 OK 03:45:17 Matched 'OK' 03:45:17 ATD*99***1# 03:45:17 CONNECT 03:45:17 Matched 'CONNECT*' 03:45:17 Connected [14241mV] 03:45:17 001 Initializing Interface: [Connect Init] 03:45:17 Initialise TCP/IP Stack 03:45:18 001 Initializing Interface: [Start PPP] 03:45:18 Connecting 03:45:20 001 Initializing Interface: [PPP Connected] 03:45:20 Connected 10.170.119.223 03:45:21 002 Initializing FTP: [Resolve Server] 03:45:21 DNS Lookup ftp.enviroscanplus.com 03:45:22 002 Initializing FTP: [Connect Server] 03:45:22 Open Connection to ftp.enviroscanplus.com 03:45:23 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 03:45:24 331 User modemtesting@enviroscanplus.com OK. Password required 03:45:25 230 OK. Current restricted directory is / 03:45:26 002 Initializing FTP: [CWD] 03:45:26 250 OK. Current directory is /HL7800 03:45:27 002 Initializing FTP: [SET Binary Mode] 03:45:27 200 TYPE is now 8-bit binary 03:45:27 003 Transferring 03:45:28 004 Uploading to Server 03:45:28 004 Uploading to Server: [Upload File] 03:45:28 227 Entering Passive Mode (198,38,77,48,195,250) 03:45:32 001 Initializing Interface 03:45:44 Disconnect 03:45:48 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&‰-%}8}'}"}(}"Où~~ÿ}#À!}%}#} }0User requesty{~ 03:45:48 NO CARRIER 03:45:48 Matched 'NO CARRIER' 03:45:48 AT+CESQ 03:45:48 +CESQ: 99,99,255,255,23,48 03:45:48 OK 03:45:48 Matched 'OK' 03:45:48 AT+CPWROFF 03:45:48 +CEREG: 0 03:45:48 +CEREG: 0 03:45:48 OK 03:45:48 Matched 'OK' 03:45:57 Error timeout 03:45:57 Power down [14271mV]