Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 14267mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-11-03 21:30:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-11-03 21:13:23 21:13:23 Initialize Modem [14314mV] 21:13:31 +CEREG: 2 21:13:31 +KSUP: 0 21:13:33 +CEREG: 0 21:13:33 +CEREG: 2 21:13:34 +CEREG: 5,"8010","08DAE50C",7 21:13:34 Matched '+CEREG: 5,*' 21:13:35 AT+KPATTERN="SOLAR" 21:13:35 Charger State = 0040 [CHARGER_STATE_CC_CV_CHARGE] 21:13:35 Charge Status = 04d [CHARGE_STATUS_IIN_LIMIT_ACTIVE] 21:13:35 Charge State Alerts = 0000 21:13:35 Charge Status Alerts = 00 21:13:35 System Status Alerts = 147 21:13:36 Unloaded Charger State = 64 [CHARGER_STATE_CC_CV_CHARGE] 21:13:36 Unloaded Charge Status = 4 [CHARGE_STATUS_IIN_LIMIT_ACTIVE] 21:13:36 Unloaded Battery Voltage = 10482mV 21:13:36 Unloaded Input Voltage = 14644mV 21:13:36 Unloaded Output Voltage = 14680mV 21:13:36 Unloaded Battery Current = 224mA 21:13:36 Unloaded Input Current = 190mA 21:13:36 BSR = 0mOhm 21:13:36 TC ChargeTimer = 0 21:13:36 TC VTimer = 0 21:13:37 Battery Voltage = 10448mV 21:13:37 Input Voltage = 14654mV 21:13:37 Output Voltage = 14680mV 21:13:37 Battery Current = 137mA 21:13:37 Input Current = 190mA 21:13:37 Die Temp = 390 x10 DegC 21:13:37 Thermistor Voltage = 10013 21:13:37 nRF Die Temp = 227 x10 DegC 21:13:37 OK 21:13:37 Matched 'OK' 21:13:37 AT+COPS? 21:13:38 +COPS: 0,0,"Hologram",7 21:13:38 OK 21:13:38 Matched 'OK' 21:13:38 AT+CESQ 21:13:38 +CESQ: 99,99,255,255,18,50 21:13:38 OK 21:13:38 Matched 'OK' 21:13:38 AT+KBND? 21:13:38 +KBND: 0,00000000000008000000 21:13:38 OK 21:13:38 Matched 'OK' 21:13:39 Connect [14277mV] 21:13:39 AT+CCLK? 21:13:39 +CCLK: "19/11/03,21:13:38+42" 21:13:39 OK 21:13:39 Matched 'OK' 21:13:39 ATS0=0 21:13:39 OK 21:13:39 Matched 'OK' 21:13:39 ATD*99***1# 21:13:39 CONNECT 21:13:39 Matched 'CONNECT*' 21:13:40 Connected [14247mV] 21:13:40 001 Initializing Interface: [Connect Init] 21:13:40 Initialise TCP/IP Stack 21:13:40 001 Initializing Interface: [Start PPP] 21:13:40 Connecting 21:13:43 001 Initializing Interface: [PPP Connected] 21:13:43 Connected 10.170.119.223 21:13:43 002 Initializing FTP: [Resolve Server] 21:13:43 DNS Lookup ftp.enviroscanplus.com 21:13:44 002 Initializing FTP: [Connect Server] 21:13:44 Open Connection to ftp.enviroscanplus.com 21:13:46 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 21:13:47 331 User modemtesting@enviroscanplus.com OK. Password required 21:13:48 230 OK. Current restricted directory is / 21:13:49 002 Initializing FTP: [CWD] 21:13:49 250 OK. Current directory is /HL7800 21:13:50 002 Initializing FTP: [SET Binary Mode] 21:13:50 200 TYPE is now 8-bit binary 21:14:01 Disconnect 21:14:05 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&†Å}%3}'}"}(}"”}6~~ÿ}#À!}%}#} }0User requesty{~ 21:14:05 NO CARRIER 21:14:05 Matched 'NO CARRIER' 21:14:05 AT+CESQ 21:14:05 +CESQ: 99,99,255,255,17,50 21:14:05 OK 21:14:05 Matched 'OK' 21:14:05 AT+CPWROFF 21:14:05 +CEREG: 0 21:14:06 +CEREG: 0 21:14:06 OK 21:14:06 Matched 'OK' 21:14:15 Error timeout 21:14:15 Power down [14227mV]