Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 14012mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-11-03 18:45:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-11-03 18:15:02 18:15:02 Initialize Modem [14053mV] 18:15:10 +CEREG: 2 18:15:10 +KSUP: 0 18:15:10 +CEREG: 0 18:15:10 +CEREG: 2 18:15:11 +CEREG: 5,"8010","08DAE50C",7 18:15:11 Matched '+CEREG: 5,*' 18:15:12 AT+KPATTERN="SOLAR" 18:15:12 Charger State = 0100 [CHARGER_STATE_CHARGER_SUSPENDED] 18:15:12 Charge Status = 00d [CHARGE_STATUS_OFF] 18:15:13 Charge State Alerts = 0000 18:15:13 Charge Status Alerts = 00 18:15:13 System Status Alerts = 000 18:15:13 Unloaded Charger State = 256 [CHARGER_STATE_CHARGER_SUSPENDED] 18:15:13 Unloaded Charge Status = 0 [CHARGE_STATUS_OFF] 18:15:13 Unloaded Battery Voltage = 10244mV 18:15:13 Unloaded Input Voltage = 14465mV 18:15:13 Unloaded Output Voltage = 14495mV 18:15:13 Unloaded Battery Current = -1mA 18:15:14 Unloaded Input Current = 24mA 18:15:14 BSR = 0mOhm 18:15:14 TC ChargeTimer = 169 18:15:14 TC VTimer = 169 18:15:14 Battery Voltage = 10245mV 18:15:14 Input Voltage = 14427mV 18:15:14 Output Voltage = 14455mV 18:15:14 Battery Current = -3mA 18:15:14 Input Current = 78mA 18:15:14 Die Temp = 265 x10 DegC 18:15:14 Thermistor Voltage = 10843 18:15:15 nRF Die Temp = 217 x10 DegC 18:15:15 OK 18:15:15 Matched 'OK' 18:15:15 AT+COPS? 18:15:15 +COPS: 0,0,"Hologram",7 18:15:15 OK 18:15:15 Matched 'OK' 18:15:15 AT+CESQ 18:15:15 +CESQ: 99,99,255,255,20,49 18:15:15 OK 18:15:15 Matched 'OK' 18:15:15 AT+KBND? 18:15:16 +KBND: 0,00000000000008000000 18:15:16 OK 18:15:16 Matched 'OK' 18:15:16 Connect [13990mV] 18:15:16 AT+CCLK? 18:15:16 +CCLK: "19/11/03,18:15:17+42" 18:15:16 OK 18:15:16 Matched 'OK' 18:15:16 ATS0=0 18:15:16 OK 18:15:16 Matched 'OK' 18:15:17 ATD*99***1# 18:15:17 CONNECT 18:15:17 Matched 'CONNECT*' 18:15:17 Connected [14006mV] 18:15:17 001 Initializing Interface: [Connect Init] 18:15:17 Initialise TCP/IP Stack 18:15:17 001 Initializing Interface: [Start PPP] 18:15:17 Connecting 18:15:20 001 Initializing Interface: [PPP Connected] 18:15:20 Connected 10.170.119.223 18:15:20 002 Initializing FTP: [Resolve Server] 18:15:20 DNS Lookup ftp.enviroscanplus.com 18:15:21 002 Initializing FTP: [Connect Server] 18:15:21 Open Connection to ftp.enviroscanplus.com 18:15:23 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 18:15:24 331 User modemtesting@enviroscanplus.com OK. Password required 18:15:25 230 OK. Current restricted directory is / 18:15:26 002 Initializing FTP: [CWD] 18:15:26 250 OK. Current directory is /HL7800 18:15:27 002 Initializing FTP: [SET Binary Mode] 18:15:27 200 TYPE is now 8-bit binary 18:15:27 003 Transferring 18:15:27 004 Uploading to Server 18:15:28 004 Uploading to Server: [Upload File] 18:15:28 227 Entering Passive Mode (198,38,77,48,202,140) 18:15:32 001 Initializing Interface 18:15:44 Disconnect 18:15:48 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&},äiú}'}"}(}"¥«~~ÿ}#À!}%}#} }0User requesty{~ 18:15:48 NO CARRIER 18:15:48 Matched 'NO CARRIER' 18:15:48 AT+CESQ 18:15:48 +CESQ: 99,99,255,255,14,47 18:15:48 OK 18:15:48 Matched 'OK' 18:15:48 AT+CPWROFF 18:15:48 +CEREG: 0 18:15:50 +CEREG: 0 18:15:50 OK 18:15:50 Matched 'OK' 18:15:59 Error timeout 18:15:59 Power down [13970mV]