Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 14069mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-11-02 18:30:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-11-02 18:00:02 18:00:02 Initialize Modem [14093mV] 18:00:10 +CEREG: 2 18:00:11 +CEREG: 0 18:00:11 +CEREG: 2 18:00:11 +KSUP: 0 18:00:12 +CEREG: 5,"8010","08DAE50C",7 18:00:12 Matched '+CEREG: 5,*' 18:00:13 AT+KPATTERN="SOLAR" 18:00:13 Charger State = 64 [CHARGER_STATE_CC_CV_CHARGE] 18:00:13 Charge Status = 8 [CHARGE_STATUS_VIN_UVCL_ACTIVE] 18:00:13 Battery Voltage = 10234mV 18:00:13 Input Voltage = 14436mV 18:00:14 Output Voltage = 14457mV 18:00:14 Battery Current = 1mA 18:00:14 Input Current = 79mA 18:00:14 Die Temp = 290 x10 DegC 18:00:14 Thermistor Voltage = 10680 18:00:14 BSR = 0mOhm 18:00:14 nRF Die Temp = 222 x10 DegC 18:00:14 Unloaded Charger State = 64 [CHARGER_STATE_CC_CV_CHARGE] 18:00:14 Unloaded Charge Status = 8 [CHARGE_STATUS_VIN_UVCL_ACTIVE] 18:00:14 Unloaded Battery Voltage = 10234mV 18:00:14 Unloaded Input Voltage = 14481mV 18:00:15 Unloaded Output Voltage = 14505mV 18:00:15 Unloaded Battery Current = 1mA 18:00:15 Unloaded Input Current = 9mA 18:00:15 OK 18:00:15 Matched 'OK' 18:00:15 AT+COPS? 18:00:15 +COPS: 0,0,"Hologram",7 18:00:15 OK 18:00:15 Matched 'OK' 18:00:15 AT+CESQ 18:00:15 +CESQ: 99,99,255,255,14,49 18:00:16 OK 18:00:16 Matched 'OK' 18:00:16 AT+KBND? 18:00:16 +KBND: 0,00000000000008000000 18:00:16 OK 18:00:16 Matched 'OK' 18:00:16 Connect [14053mV] 18:00:16 AT+CCLK? 18:00:16 +CCLK: "19/11/02,18:00:16+42" 18:00:16 OK 18:00:16 Matched 'OK' 18:00:17 ATS0=0 18:00:17 OK 18:00:17 Matched 'OK' 18:00:17 ATD*99***1# 18:00:17 CONNECT 18:00:17 Matched 'CONNECT*' 18:00:17 Connected [14049mV] 18:00:17 001 Initializing Interface: [Connect Init] 18:00:17 Initialise TCP/IP Stack 18:00:18 001 Initializing Interface: [Start PPP] 18:00:18 Connecting 18:00:20 001 Initializing Interface: [PPP Connected] 18:00:20 Connected 10.170.119.223 18:00:21 002 Initializing FTP: [Resolve Server] 18:00:21 DNS Lookup ftp.enviroscanplus.com 18:00:22 002 Initializing FTP: [Connect Server] 18:00:22 Open Connection to ftp.enviroscanplus.com 18:00:23 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 18:00:24 331 User modemtesting@enviroscanplus.com OK. Password required 18:00:25 230 OK. Current restricted directory is / 18:00:26 002 Initializing FTP: [CWD] 18:00:26 250 OK. Current directory is /HL7800 18:00:27 002 Initializing FTP: [SET Binary Mode] 18:00:27 200 TYPE is now 8-bit binary 18:00:27 003 Transferring 18:00:28 004 Uploading to Server 18:00:29 004 Uploading to Server: [Upload File] 18:00:29 227 Entering Passive Mode (198,38,77,48,202,140) 18:00:36 001 Initializing Interface 18:01:16 Disconnect 18:01:21 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&×A¯;}'}"}(}"%³~~ÿ}#À!}%}#} }0User requesty{~ 18:01:21 NO CARRIER 18:01:21 Matched 'NO CARRIER' 18:01:21 AT+CESQ 18:01:21 +CESQ: 99,99,255,255,12,47 18:01:21 OK 18:01:21 Matched 'OK' 18:01:21 AT+CPWROFF 18:01:21 +CEREG: 0 18:01:21 +CEREG: 0 18:01:21 OK 18:01:21 Matched 'OK' 18:01:30 Error timeout 18:01:30 Power down [14010mV]