Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 12848mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-11-02 14:15:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-11-02 13:45:02 13:45:02 Initialize Modem [12877mV] 13:45:10 +CEREG: 2 13:45:10 +KSUP: 0 13:45:10 +CEREG: 0 13:45:10 +CEREG: 2 13:45:11 +CEREG: 5,"8010","08DAE50C",7 13:45:11 Matched '+CEREG: 5,*' 13:45:12 AT+KPATTERN="SOLAR" 13:45:12 Charger State = 64 [CHARGER_STATE_CC_CV_CHARGE] 13:45:12 Charge Status = 1 [CHARGE_STATUS_CONSTANT_VOLTAGE] 13:45:13 Battery Voltage = 10255mV 13:45:13 Input Voltage = 13205mV 13:45:13 Output Voltage = 13228mV 13:45:13 Battery Current = 1mA 13:45:13 Input Current = 79mA 13:45:13 Die Temp = 283 x10 DegC 13:45:13 Thermistor Voltage = 10784 13:45:13 BSR = 0mOhm 13:45:13 nRF Die Temp = 215 x10 DegC 13:45:13 Unloaded Charger State = 64 [CHARGER_STATE_CC_CV_CHARGE] 13:45:13 Unloaded Charge Status = 8 [CHARGE_STATUS_CONSTANT_VOLTAGE] 13:45:14 Unloaded Battery Voltage = 10255mV 13:45:14 Unloaded Input Voltage = 13239mV 13:45:14 Unloaded Output Voltage = 13263mV 13:45:14 Unloaded Battery Current = 1mA 13:45:14 Unloaded Input Current = 24mA 13:45:14 OK 13:45:14 Matched 'OK' 13:45:14 AT+COPS? 13:45:14 +COPS: 0,0,"Hologram",7 13:45:14 OK 13:45:14 Matched 'OK' 13:45:15 AT+CESQ 13:45:15 +CESQ: 99,99,255,255,22,50 13:45:15 OK 13:45:15 Matched 'OK' 13:45:15 AT+KBND? 13:45:15 +KBND: 0,00000000000008000000 13:45:15 OK 13:45:15 Matched 'OK' 13:45:15 Connect [12757mV] 13:45:15 AT+CCLK? 13:45:16 +CCLK: "19/11/02,13:45:16+42" 13:45:16 OK 13:45:16 Matched 'OK' 13:45:16 ATS0=0 13:45:16 OK 13:45:16 Matched 'OK' 13:45:16 ATD*99***1# 13:45:16 CONNECT 13:45:16 Matched 'CONNECT*' 13:45:16 Connected [12780mV] 13:45:17 001 Initializing Interface: [Connect Init] 13:45:17 Initialise TCP/IP Stack 13:45:17 001 Initializing Interface: [Start PPP] 13:45:17 Connecting 13:45:20 001 Initializing Interface: [PPP Connected] 13:45:20 Connected 10.170.119.223 13:45:20 002 Initializing FTP: [Resolve Server] 13:45:20 DNS Lookup ftp.enviroscanplus.com 13:45:21 002 Initializing FTP: [Connect Server] 13:45:21 Open Connection to ftp.enviroscanplus.com 13:45:23 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 13:45:24 331 User modemtesting@enviroscanplus.com OK. Password required 13:45:24 230 OK. Current restricted directory is / 13:45:25 002 Initializing FTP: [CWD] 13:45:25 250 OK. Current directory is /HL7800 13:45:26 002 Initializing FTP: [SET Binary Mode] 13:45:26 200 TYPE is now 8-bit binary 13:45:27 003 Transferring 13:45:27 004 Uploading to Server 13:45:28 004 Uploading to Server: [Upload File] 13:45:28 227 Entering Passive Mode (198,38,77,48,196,72) 13:45:32 001 Initializing Interface 13:45:44 Disconnect 13:45:48 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&}<Ì}(ø}'}"}(}" Ø~~ÿ}#À!}%}#} }0User requesty{~ 13:45:48 NO CARRIER 13:45:48 Matched 'NO CARRIER' 13:45:48 AT+CESQ 13:45:48 +CESQ: 99,99,255,255,18,47 13:45:48 OK 13:45:48 Matched 'OK' 13:45:48 AT+CPWROFF 13:45:48 +CEREG: 0 13:45:48 +CEREG: 0 13:45:48 OK 13:45:48 Matched 'OK' 13:45:57 Error timeout 13:45:57 Power down [12759mV]