Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 12917mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-11-02 11:30:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-11-02 11:00:02 11:00:02 Initialize Modem [12699mV] 11:00:10 +CEREG: 2 11:00:10 +CEREG: 0 11:00:10 +CEREG: 2 11:00:10 +KSUP: 0 11:00:12 +CEREG: 5,"8010","08DAE50C",7 11:00:12 Matched '+CEREG: 5,*' 11:00:13 AT+KPATTERN="SOLAR" 11:00:13 Charger State = 64 [CHARGER_STATE_CC_CV_CHARGE] 11:00:14 Charge Status = 8 [CHARGE_STATUS_VIN_UVCL_ACTIVE] 11:00:14 Battery Voltage = 10010mV 11:00:14 Input Voltage = 13096mV 11:00:14 Output Voltage = 13114mV 11:00:14 Battery Current = 59mA 11:00:14 Input Current = 110mA 11:00:14 Die Temp = 294 x10 DegC 11:00:14 Thermistor Voltage = 11108 11:00:14 BSR = 0mOhm 11:00:14 nRF Die Temp = 195 x10 DegC 11:00:15 Unloaded Charger State = 64 [CHARGER_STATE_CC_CV_CHARGE] 11:00:15 Unloaded Charge Status = 8 [CHARGE_STATUS_VIN_UVCL_ACTIVE] 11:00:15 Unloaded Battery Voltage = 10035mV 11:00:15 Unloaded Input Voltage = 13238mV 11:00:15 Unloaded Output Voltage = 13257mV 11:00:15 Unloaded Battery Current = 105mA 11:00:15 Unloaded Input Current = 112mA 11:00:15 OK 11:00:15 Matched 'OK' 11:00:15 AT+COPS? 11:00:15 +COPS: 0,0,"Hologram",7 11:00:16 OK 11:00:16 Matched 'OK' 11:00:16 AT+CESQ 11:00:16 +CESQ: 99,99,255,255,18,49 11:00:16 OK 11:00:16 Matched 'OK' 11:00:16 AT+KBND? 11:00:16 +KBND: 0,00000000000008000000 11:00:16 OK 11:00:16 Matched 'OK' 11:00:16 Connect [12883mV] 11:00:17 AT+CCLK? 11:00:17 +CCLK: "19/11/02,11:00:17+42" 11:00:17 OK 11:00:17 Matched 'OK' 11:00:17 ATS0=0 11:00:17 OK 11:00:17 Matched 'OK' 11:00:17 ATD*99***1# 11:00:17 CONNECT 11:00:17 Matched 'CONNECT*' 11:00:18 Connected [12826mV] 11:00:18 001 Initializing Interface: [Connect Init] 11:00:18 Initialise TCP/IP Stack 11:00:18 001 Initializing Interface: [Start PPP] 11:00:18 Connecting 11:00:21 001 Initializing Interface: [PPP Connected] 11:00:21 Connected 10.170.119.223 11:00:21 002 Initializing FTP: [Resolve Server] 11:00:21 DNS Lookup ftp.enviroscanplus.com 11:00:22 002 Initializing FTP: [Connect Server] 11:00:22 Open Connection to ftp.enviroscanplus.com 11:00:24 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 11:00:25 331 User modemtesting@enviroscanplus.com OK. Password required 11:00:26 230 OK. Current restricted directory is / 11:00:27 002 Initializing FTP: [CWD] 11:00:27 250 OK. Current directory is /HL7800 11:00:28 002 Initializing FTP: [SET Binary Mode] 11:00:28 200 TYPE is now 8-bit binary 11:00:28 003 Transferring 11:00:28 004 Uploading to Server 11:00:29 004 Uploading to Server: [Upload File] 11:00:29 227 Entering Passive Mode (198,38,77,48,200,237) 11:00:33 001 Initializing Interface 11:00:45 Disconnect 11:00:49 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&²v})A}'}"}(}"t'~~ÿ}#À!}%}#} }0User requesty{~ 11:00:49 NO CARRIER 11:00:49 Matched 'NO CARRIER' 11:00:49 AT+CESQ 11:00:49 +CESQ: 99,99,255,255,8,47 11:00:49 OK 11:00:49 Matched 'OK' 11:00:49 AT+CPWROFF 11:00:49 +CEREG: 0 11:00:49 +CEREG: 0 11:00:49 OK 11:00:49 Matched 'OK' 11:00:58 Error timeout 11:00:58 Power down [11770mV]