Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 14488mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-11-01 17:30:00 -- Interval: 2m 0s (1 x 120s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-11-01 17:26:02 17:26:02 Initialize Modem [14625mV] 17:26:09 +KSUP: 0 17:26:10 +CEREG: 2 17:26:10 +CEREG: 0 17:26:10 +CEREG: 2 17:26:11 +CEREG: 5,"8002","08D9CA0B",7 17:26:11 Matched '+CEREG: 5,*' 17:26:13 AT+KPATTERN="SOLAR" 17:26:13 Charger State = 64 [CHARGER_STATE_CC_CV_CHARGE] 17:26:13 Charge Status = 8 [CHARGE_STATUS_VIN_UVCL_ACTIVE] 17:26:13 Battery Voltage = 10082mV 17:26:13 Input Voltage = 14498mV 17:26:13 Output Voltage = 14519mV 17:26:13 Battery Current = 164mA 17:26:13 Input Current = 202mA 17:26:13 Die Temp = 372 x10 DegC 17:26:13 Thermistor Voltage = 9583 17:26:14 BSR = 0mOhm 17:26:14 nRF Die Temp = 272 x10 DegC 17:26:14 Unloaded Charger State = 64 [CHARGER_STATE_CC_CV_CHARGE] 17:26:14 Unloaded Charge Status = 8 [CHARGE_STATUS_VIN_UVCL_ACTIVE] 17:26:14 Unloaded Battery Voltage = 10100mV 17:26:14 Unloaded Input Voltage = 11971mV 17:26:14 Unloaded Output Voltage = 11987mV 17:26:14 Unloaded Battery Current = 202mA 17:26:14 Unloaded Input Current = 206mA 17:26:14 OK 17:26:14 Matched 'OK' 17:26:15 AT+COPS? 17:26:15 +COPS: 0,0,"Hologram",7 17:26:15 OK 17:26:15 Matched 'OK' 17:26:15 AT+CESQ 17:26:15 +CESQ: 99,99,255,255,6,34 17:26:15 OK 17:26:15 Matched 'OK' 17:26:15 AT+KBND? 17:26:15 +KBND: 0,00000000000008000000 17:26:15 OK 17:26:15 Matched 'OK' 17:26:16 Connect [14166mV] 17:26:16 AT+CCLK? 17:26:16 +CCLK: "19/11/01,17:26:16+42" 17:26:16 OK 17:26:16 Matched 'OK' 17:26:16 ATS0=0 17:26:16 OK 17:26:16 Matched 'OK' 17:26:16 ATD*99***1# 17:26:16 CONNECT 17:26:16 Matched 'CONNECT*' 17:26:17 Connected [14196mV] 17:26:17 001 Initializing Interface: [Connect Init] 17:26:17 Initialise TCP/IP Stack 17:26:17 001 Initializing Interface: [Start PPP] 17:26:17 Connecting 17:26:20 001 Initializing Interface: [PPP Connected] 17:26:20 Connected 10.170.119.223 17:26:20 002 Initializing FTP: [Resolve Server] 17:26:20 DNS Lookup ftp.enviroscanplus.com 17:26:21 002 Initializing FTP: [Connect Server] 17:26:21 Open Connection to ftp.enviroscanplus.com 17:26:23 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 17:26:24 331 User modemtesting@enviroscanplus.com OK. Password required 17:26:25 230 OK. Current restricted directory is / 17:26:26 002 Initializing FTP: [CWD] 17:26:26 250 OK. Current directory is /HL7800 17:26:27 002 Initializing FTP: [SET Binary Mode] 17:26:27 200 TYPE is now 8-bit binary 17:26:27 003 Transferring 17:26:27 004 Uploading to Server 17:26:28 004 Uploading to Server: [Upload File] 17:26:28 227 Entering Passive Mode (198,38,77,48,195,194) 17:26:32 001 Initializing Interface 17:26:44 Disconnect 17:26:48 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&1}$}^¯}'}"}(}"?Ó~~ÿ}#À!}%}#} }0User requesty{~ 17:26:48 NO CARRIER 17:26:48 Matched 'NO CARRIER' 17:26:48 AT+CESQ 17:26:48 +CESQ: 99,99,255,255,14,38 17:26:48 OK 17:26:48 Matched 'OK' 17:26:48 AT+CPWROFF 17:26:48 +CEREG: 0 17:26:49 +CEREG: 0 17:26:49 OK 17:26:49 Matched 'OK' 17:26:58 Error timeout 17:26:58 Power down [14514mV]