Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 14514mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-11-01 17:10:00 -- Interval: 2m 0s (1 x 120s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-11-01 17:06:02 17:06:02 Initialize Modem [14555mV] 17:06:10 +CEREG: 2 17:06:10 +KSUP: 0 17:06:10 +CEREG: 0 17:06:10 +CEREG: 2 17:06:11 +CEREG: 5,"8002","08D9CA0B",7 17:06:11 Matched '+CEREG: 5,*' 17:06:12 AT+KPATTERN="SOLAR" 17:06:12 Charger State = 64 [CHARGER_STATE_CC_CV_CHARGE] 17:06:12 Charge Status = 0 [CHARGE_STATUS_OFF] 17:06:12 Battery Voltage = 9978mV 17:06:12 Input Voltage = 14948mV 17:06:12 Output Voltage = 14976mV 17:06:12 Battery Current = -3mA 17:06:12 Input Current = 73mA 17:06:12 Die Temp = 343 x10 DegC 17:06:13 Thermistor Voltage = 9778 17:06:13 BSR = 0mOhm 17:06:13 nRF Die Temp = 270 x10 DegC 17:06:13 Unloaded Charger State = 64 [CHARGER_STATE_CC_CV_CHARGE] 17:06:13 Unloaded Charge Status = 0 [CHARGE_STATUS_OFF] 17:06:13 Unloaded Battery Voltage = 9978mV 17:06:13 Unloaded Input Voltage = 14948mV 17:06:13 Unloaded Output Voltage = 14976mV 17:06:13 Unloaded Battery Current = -3mA 17:06:13 Unloaded Input Current = 73mA 17:06:14 OK 17:06:14 Matched 'OK' 17:06:14 AT+COPS? 17:06:14 +COPS: 0,0,"Hologram",7 17:06:14 OK 17:06:14 Matched 'OK' 17:06:14 AT+CESQ 17:06:14 +CESQ: 99,99,255,255,0,31 17:06:14 OK 17:06:14 Matched 'OK' 17:06:14 AT+KBND? 17:06:14 +KBND: 0,00000000000008000000 17:06:15 OK 17:06:15 Matched 'OK' 17:06:15 Connect [14528mV] 17:06:15 AT+CCLK? 17:06:15 +CCLK: "19/11/01,17:06:15+42" 17:06:15 OK 17:06:15 Matched 'OK' 17:06:15 ATS0=0 17:06:15 OK 17:06:15 Matched 'OK' 17:06:15 ATD*99***1# 17:06:16 CONNECT 17:06:16 Matched 'CONNECT*' 17:06:16 Connected [14500mV] 17:06:16 001 Initializing Interface: [Connect Init] 17:06:16 Initialise TCP/IP Stack 17:06:16 001 Initializing Interface: [Start PPP] 17:06:16 Connecting 17:06:19 001 Initializing Interface: [PPP Connected] 17:06:19 Connected 10.170.119.223 17:06:19 002 Initializing FTP: [Resolve Server] 17:06:19 DNS Lookup ftp.enviroscanplus.com 17:06:20 002 Initializing FTP: [Connect Server] 17:06:20 Open Connection to ftp.enviroscanplus.com 17:06:22 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 17:06:23 331 User modemtesting@enviroscanplus.com OK. Password required 17:06:24 230 OK. Current restricted directory is / 17:06:25 002 Initializing FTP: [CWD] 17:06:25 250 OK. Current directory is /HL7800 17:06:26 002 Initializing FTP: [SET Binary Mode] 17:06:26 200 TYPE is now 8-bit binary 17:06:26 003 Transferring 17:06:27 004 Uploading to Server 17:06:28 004 Uploading to Server: [Upload File] 17:06:28 227 Entering Passive Mode (198,38,77,48,199,22) 17:06:31 001 Initializing Interface 17:06:43 Disconnect 17:06:47 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&Îz5)}'}"}(}"B(~~ÿ}#À!}%}#} }0User requesty{~ 17:06:47 NO CARRIER 17:06:47 Matched 'NO CARRIER' 17:06:47 AT+CESQ 17:06:47 +CESQ: 99,99,255,255,5,33 17:06:47 OK 17:06:47 Matched 'OK' 17:06:48 AT+CPWROFF 17:06:48 +CEREG: 0 17:06:48 +CEREG: 0 17:06:49 OK 17:06:49 Matched 'OK' 17:06:58 Error timeout 17:06:58 Power down [14484mV]