Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 14472mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-11-01 17:06:00 -- Interval: 2m 0s (1 x 120s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-11-01 17:02:02 17:02:02 Initialize Modem [14627mV] 17:02:02 001 Initializing Interface: [Connect Modem] 17:02:02 Waiting Network 17:02:10 +CEREG: 2 17:02:10 +KSUP: 0 17:02:13 +CEREG: 0 17:02:13 +CEREG: 2 17:02:16 +CEREG: 5,"8002","08D9CA0B",7 17:02:16 Matched '+CEREG: 5,*' 17:02:17 AT+KPATTERN="SOLAR" 17:02:17 Charger State = 64 [CHARGER_STATE_CC_CV_CHARGE] 17:02:17 Charge Status = 0 [CHARGE_STATUS_OFF] 17:02:17 Battery Voltage = 9978mV 17:02:17 Input Voltage = 14948mV 17:02:17 Output Voltage = 14976mV 17:02:17 Battery Current = -3mA 17:02:17 Input Current = 73mA 17:02:17 Die Temp = 343 x10 DegC 17:02:17 Thermistor Voltage = 9778 17:02:18 BSR = 0mOhm 17:02:18 nRF Die Temp = 270 x10 DegC 17:02:18 Unloaded Charger State = 64 [CHARGER_STATE_CC_CV_CHARGE] 17:02:18 Unloaded Charge Status = 0 [CHARGE_STATUS_OFF] 17:02:18 Unloaded Battery Voltage = 9978mV 17:02:18 Unloaded Input Voltage = 14948mV 17:02:18 Unloaded Output Voltage = 14976mV 17:02:18 Unloaded Battery Current = -3mA 17:02:18 Unloaded Input Current = 73mA 17:02:18 OK 17:02:18 Matched 'OK' 17:02:19 AT+COPS? 17:02:19 +COPS: 0,0,"Hologram",7 17:02:19 OK 17:02:19 Matched 'OK' 17:02:19 AT+CESQ 17:02:19 +CESQ: 99,99,255,255,18,35 17:02:19 OK 17:02:19 Matched 'OK' 17:02:19 AT+KBND? 17:02:19 +KBND: 0,00000000000008000000 17:02:19 OK 17:02:19 Matched 'OK' 17:02:20 Connect [14551mV] 17:02:20 AT+CCLK? 17:02:20 +CCLK: "19/11/01,17:02:20+42" 17:02:20 OK 17:02:20 Matched 'OK' 17:02:20 ATS0=0 17:02:20 OK 17:02:20 Matched 'OK' 17:02:20 ATD*99***1# 17:02:20 CONNECT 17:02:20 Matched 'CONNECT*' 17:02:21 Connected [14536mV] 17:02:21 001 Initializing Interface: [Connect Init] 17:02:21 Initialise TCP/IP Stack 17:02:21 001 Initializing Interface: [Start PPP] 17:02:21 Connecting 17:02:24 001 Initializing Interface: [PPP Connected] 17:02:24 Connected 10.170.119.223 17:02:24 002 Initializing FTP: [Resolve Server] 17:02:24 DNS Lookup ftp.enviroscanplus.com 17:02:25 002 Initializing FTP: [Connect Server] 17:02:25 Open Connection to ftp.enviroscanplus.com 17:02:27 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 17:02:28 331 User modemtesting@enviroscanplus.com OK. Password required 17:02:29 230 OK. Current restricted directory is / 17:02:30 002 Initializing FTP: [CWD] 17:02:30 250 OK. Current directory is /HL7800 17:02:31 002 Initializing FTP: [SET Binary Mode] 17:02:31 200 TYPE is now 8-bit binary 17:02:32 003 Transferring 17:02:32 004 Uploading to Server 17:02:33 004 Uploading to Server: [Upload File] 17:02:33 227 Entering Passive Mode (198,38,77,48,195,103) 17:02:38 003 Transferring 17:02:38 004 Uploading to Server 17:02:39 227 Entering Passive Mode (198,38,77,48,197,212) 17:02:43 003 Transferring 17:02:44 004 Uploading to Server 17:02:45 227 Entering Passive Mode (198,38,77,48,202,20) 17:02:49 001 Initializing Interface 17:03:12 Disconnect 17:03:16 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&€¶¸Ö}'}"}(}"}8H~~ÿ}#À!}%}#} }0User requesty{~ 17:03:16 NO CARRIER 17:03:16 Matched 'NO CARRIER' 17:03:16 AT+CESQ 17:03:16 +CESQ: 99,99,255,255,0,33 17:03:16 OK 17:03:16 Matched 'OK' 17:03:16 AT+CPWROFF 17:03:17 +CEREG: 0 17:03:17 +CEREG: 0 17:03:17 OK 17:03:17 Matched 'OK' 17:03:26 Error timeout 17:03:26 Power down [14500mV]