Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 08922mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-11-01 15:30:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-11-01 15:00:02 15:00:02 Initialize Modem [09065mV] 15:00:09 +KSUP: 0 15:00:10 +CEREG: 2 15:00:10 +CEREG: 0 15:00:10 +CEREG: 2 15:00:11 +CEREG: 5,"8003","08D9BF0D",7 15:00:11 Matched '+CEREG: 5,*' 15:00:12 AT+KPATTERN="SOLAR" 15:00:12 Charger State = 256 [CHARGER_STATE_CHARGER_SUSPENDED] 15:00:12 Charge Status = 0 [CHARGE_STATUS_OFF] 15:00:12 Battery Voltage = 9485mV 15:00:12 Input Voltage = 9361mV 15:00:12 Output Voltage = 9488mV 15:00:12 Battery Current = 0mA 15:00:12 Input Current = 1mA 15:00:12 Die Temp = 347 x10 DegC 15:00:12 Thermistor Voltage = 9706 15:00:13 BSR = 0mOhm 15:00:13 nRF Die Temp = 295 x10 DegC 15:00:13 Unloaded Charger State = 256 [CHARGER_STATE_CHARGER_SUSPENDED] 15:00:13 Unloaded Charge Status = 0 [CHARGE_STATUS_OFF] 15:00:13 Unloaded Battery Voltage = 9525mV 15:00:13 Unloaded Input Voltage = 9402mV 15:00:13 Unloaded Output Voltage = 9539mV 15:00:13 Unloaded Battery Current = 0mA 15:00:13 Unloaded Input Current = 1mA 15:00:13 OK 15:00:13 Matched 'OK' 15:00:14 AT+COPS? 15:00:14 +COPS: 0,0,"Hologram",7 15:00:14 OK 15:00:14 Matched 'OK' 15:00:14 AT+CESQ 15:00:14 +CESQ: 99,99,255,255,13,52 15:00:14 OK 15:00:14 Matched 'OK' 15:00:14 AT+KBND? 15:00:14 +KBND: 0,00000000000008000000 15:00:14 OK 15:00:14 Matched 'OK' 15:00:15 Connect [08968mV] 15:00:15 AT+CCLK? 15:00:15 +CCLK: "19/11/01,15:00:15+42" 15:00:15 OK 15:00:15 Matched 'OK' 15:00:15 ATS0=0 15:00:15 OK 15:00:15 Matched 'OK' 15:00:15 ATD*99***1# 15:00:15 CONNECT 15:00:15 Matched 'CONNECT*' 15:00:16 Connected [08962mV] 15:00:16 001 Initializing Interface: [Connect Init] 15:00:16 Initialise TCP/IP Stack 15:00:16 001 Initializing Interface: [Start PPP] 15:00:16 Connecting 15:00:19 001 Initializing Interface: [PPP Connected] 15:00:19 Connected 10.170.119.223 15:00:19 002 Initializing FTP: [Resolve Server] 15:00:19 DNS Lookup ftp.enviroscanplus.com 15:00:20 002 Initializing FTP: [Connect Server] 15:00:20 Open Connection to ftp.enviroscanplus.com 15:00:22 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 15:00:22 331 User modemtesting@enviroscanplus.com OK. Password required 15:00:23 230 OK. Current restricted directory is / 15:00:24 002 Initializing FTP: [CWD] 15:00:24 250 OK. Current directory is /HL7800 15:00:24 002 Initializing FTP: [SET Binary Mode] 15:00:24 200 TYPE is now 8-bit binary 15:00:25 003 Transferring 15:00:25 004 Uploading to Server 15:00:26 004 Uploading to Server: [Upload File] 15:00:26 227 Entering Passive Mode (198,38,77,48,202,25) 15:00:29 001 Initializing Interface 15:00:39 Disconnect 15:00:43 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&:þUÔ}'}"}(}"}/ð~~ÿ}#À!}%}#} }0User requesty{~ 15:00:43 NO CARRIER 15:00:43 Matched 'NO CARRIER' 15:00:43 AT+CESQ 15:00:43 +CESQ: 99,99,255,255,17,53 15:00:43 OK 15:00:43 Matched 'OK' 15:00:43 AT+CPWROFF 15:00:43 +CEREG: 0 15:00:43 +CEREG: 0 15:00:44 OK 15:00:44 Matched 'OK' 15:00:52 Error timeout 15:00:53 Power down [08418mV]