Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 08968mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-11-01 15:15:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-11-01 14:45:02 14:45:02 Initialize Modem [09049mV] 14:45:10 +CEREG: 2 14:45:10 +KSUP: 0 14:45:10 +CEREG: 0 14:45:10 +CEREG: 2 14:45:11 +CEREG: 5,"8003","08DCAF0C",7 14:45:11 Matched '+CEREG: 5,*' 14:45:11 AT+KPATTERN="SOLAR" 14:45:11 Charger State = 256 [CHARGER_STATE_CHARGER_SUSPENDED] 14:45:12 Charge Status = 0 [CHARGE_STATUS_OFF] 14:45:12 Battery Voltage = 9499mV 14:45:12 Input Voltage = 9297mV 14:45:12 Output Voltage = 9496mV 14:45:12 Battery Current = 0mA 14:45:12 Input Current = 0mA 14:45:12 Die Temp = 344 x10 DegC 14:45:12 Thermistor Voltage = 9744 14:45:12 BSR = 0mOhm 14:45:12 nRF Die Temp = 295 x10 DegC 14:45:13 Unloaded Charger State = 256 [CHARGER_STATE_CHARGER_SUSPENDED] 14:45:13 Unloaded Charge Status = 0 [CHARGE_STATUS_OFF] 14:45:13 Unloaded Battery Voltage = 9538mV 14:45:13 Unloaded Input Voltage = 9453mV 14:45:13 Unloaded Output Voltage = 9549mV 14:45:13 Unloaded Battery Current = 0mA 14:45:13 Unloaded Input Current = 1mA 14:45:13 OK 14:45:13 Matched 'OK' 14:45:13 AT+COPS? 14:45:13 +COPS: 0,0,"Hologram",7 14:45:14 OK 14:45:14 Matched 'OK' 14:45:14 AT+CESQ 14:45:14 +CESQ: 99,99,255,255,8,42 14:45:14 OK 14:45:14 Matched 'OK' 14:45:14 AT+KBND? 14:45:14 +KBND: 0,00000000000008000000 14:45:14 OK 14:45:14 Matched 'OK' 14:45:14 Connect [08970mV] 14:45:15 AT+CCLK? 14:45:15 +CCLK: "19/11/01,14:45:14+42" 14:45:15 OK 14:45:15 Matched 'OK' 14:45:15 ATS0=0 14:45:15 OK 14:45:15 Matched 'OK' 14:45:15 ATD*99***1# 14:45:15 CONNECT 14:45:15 Matched 'CONNECT*' 14:45:16 Connected [08991mV] 14:45:16 001 Initializing Interface: [Connect Init] 14:45:16 Initialise TCP/IP Stack 14:45:16 001 Initializing Interface: [Start PPP] 14:45:16 Connecting 14:45:19 001 Initializing Interface: [PPP Connected] 14:45:19 Connected 10.170.119.223 14:45:19 002 Initializing FTP: [Resolve Server] 14:45:19 DNS Lookup ftp.enviroscanplus.com 14:45:20 002 Initializing FTP: [Connect Server] 14:45:20 Open Connection to ftp.enviroscanplus.com 14:45:22 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 14:45:23 331 User modemtesting@enviroscanplus.com OK. Password required 14:45:24 230 OK. Current restricted directory is / 14:45:25 002 Initializing FTP: [CWD] 14:45:25 250 OK. Current directory is /HL7800 14:45:25 002 Initializing FTP: [SET Binary Mode] 14:45:25 200 TYPE is now 8-bit binary 14:45:26 003 Transferring 14:45:26 004 Uploading to Server 14:45:27 004 Uploading to Server: [Upload File] 14:45:27 227 Entering Passive Mode (198,38,77,48,200,138) 14:45:31 001 Initializing Interface 14:45:45 Disconnect 14:45:49 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&çoŠm}'}"}(}"}2d~~ÿ}#À!}%}#} }0User requesty{~ 14:45:49 NO CARRIER 14:45:49 Matched 'NO CARRIER' 14:45:49 AT+CESQ 14:45:49 +CESQ: 99,99,255,255,0,39 14:45:49 OK 14:45:49 Matched 'OK' 14:45:49 AT+CPWROFF 14:45:49 +CEREG: 0 14:45:49 +CEREG: 0 14:45:49 OK 14:45:49 Matched 'OK' 14:45:58 Error timeout 14:45:58 Power down [08932mV]