Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 14522mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-10-30 04:00:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-10-30 03:30:02 03:30:02 Initialize Modem [14571mV] 03:30:15 ªÿªÿªÿªÿªÿªÿªÿªÿªÿªÿªÿªÿ}ß}ß}ß—mÊe2ÿ 03:30:15 +CEREG: 2 03:30:16 +CEREG: 0 03:30:16 +CEREG: 2 03:30:16 +KSUP: 0 03:30:17 +CEREG: 5,"8002","08D9CA0B",7 03:30:17 Matched '+CEREG: 5,*' 03:30:17 AT+KPATTERN="SOLAR" 03:30:17 Charger State = 64 [CHARGER_STATE_CC_CV_CHARGE] 03:30:18 Charge Status = 4 [CHARGE_STATUS_IIN_LIMIT_ACTIVE] 03:30:18 Battery Voltage = 10507mV 03:30:18 Input Voltage = 14928mV 03:30:18 Output Voltage = 14956mV 03:30:18 Battery Current = -1mA 03:30:18 Input Current = 74mA 03:30:18 Die Temp = 289 x10 DegC 03:30:18 Thermistor Voltage = 10881 03:30:18 BSR = 0mOhm 03:30:18 OK 03:30:18 Matched 'OK' 03:30:19 AT+COPS? 03:30:19 +COPS: 0,0,"Hologram",7 03:30:19 OK 03:30:19 Matched 'OK' 03:30:19 AT+CESQ 03:30:19 +CESQ: 99,99,255,255,15,37 03:30:19 OK 03:30:19 Matched 'OK' 03:30:19 AT+KBND? 03:30:19 +KBND: 0,00000000000008000000 03:30:19 OK 03:30:19 Matched 'OK' 03:30:20 Connect [14573mV] 03:30:20 AT+CCLK? 03:30:20 +CCLK: "19/10/30,03:30:19+42" 03:30:20 OK 03:30:20 Matched 'OK' 03:30:20 ATS0=0 03:30:20 OK 03:30:20 Matched 'OK' 03:30:20 ATD*99***1# 03:30:20 CONNECT 03:30:20 Matched 'CONNECT*' 03:30:21 Connected [14546mV] 03:30:21 001 Initializing Interface: [Connect Init] 03:30:21 Initialise TCP/IP Stack 03:30:21 001 Initializing Interface: [Start PPP] 03:30:21 Connecting 03:30:24 001 Initializing Interface: [PPP Connected] 03:30:24 Connected 10.170.119.223 03:30:24 002 Initializing FTP: [Resolve Server] 03:30:24 DNS Lookup ftp.enviroscanplus.com 03:30:25 002 Initializing FTP: [Connect Server] 03:30:25 Open Connection to ftp.enviroscanplus.com 03:30:27 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 03:30:28 331 User modemtesting@enviroscanplus.com OK. Password required 03:30:29 230 OK. Current restricted directory is / 03:30:30 002 Initializing FTP: [CWD] 03:30:30 250 OK. Current directory is /HL7800 03:30:31 002 Initializing FTP: [SET Binary Mode] 03:30:31 200 TYPE is now 8-bit binary 03:30:31 003 Transferring 03:30:31 004 Uploading to Server 03:30:32 004 Uploading to Server: [Upload File] 03:30:32 227 Entering Passive Mode (198,38,77,48,202,234) 03:30:36 001 Initializing Interface 03:30:47 Disconnect 03:30:51 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&xMò©}'}"}(}"<“~~ÿ}#À!}%}#} }0User requesty{~ 03:30:51 NO CARRIER 03:30:51 Matched 'NO CARRIER' 03:30:51 AT+CESQ 03:30:51 +CESQ: 99,99,255,255,17,37 03:30:51 OK 03:30:51 Matched 'OK' 03:30:51 AT+CPWROFF 03:30:51 +CEREG: 0 03:30:51 +CEREG: 0 03:30:51 OK 03:30:51 Matched 'OK' 03:31:00 Error timeout 03:31:00 Power down [14538mV]