Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 09339mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-10-27 08:45:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-10-27 08:15:02 08:15:02 Initialize Modem [09936mV] 08:15:09 +CEREG: 2 08:15:10 +KSUP: 0 08:15:10 +CEREG: 0 08:15:10 +CEREG: 2 08:15:11 +CEREG: 5,"8010","08DAE50C",7 08:15:11 Matched '+CEREG: 5,*' 08:15:11 AT+KPATTERN="SOLAR" 08:15:11 Charger State = 256 [CHARGER_STATE_CHARGER_SUSPENDED] 08:15:11 Charge Status = 0 [CHARGE_STATUS_OFF] 08:15:12 Battery Voltage = 10411mV 08:15:12 Input Voltage = 10444mV 08:15:12 Output Voltage = 9888mV 08:15:12 Battery Current = 0mA 08:15:12 Input Current = 6mA 08:15:12 Die Temp = 217 x10 DegC 08:15:12 Thermistor Voltage = 13017 08:15:12 BSR = 0mOhm 08:15:12 OK 08:15:12 Matched 'OK' 08:15:12 AT+COPS? 08:15:13 +COPS: 0,0,"Hologram",7 08:15:13 OK 08:15:13 Matched 'OK' 08:15:13 AT+CESQ 08:15:13 +CESQ: 99,99,255,255,9,51 08:15:13 OK 08:15:13 Matched 'OK' 08:15:13 AT+KBND? 08:15:13 +KBND: 0,00000000000008000000 08:15:13 OK 08:15:13 Matched 'OK' 08:15:14 Connect [09404mV] 08:15:14 AT+CCLK? 08:15:14 +CCLK: "19/10/27,08:15:08+42" 08:15:14 OK 08:15:14 Matched 'OK' 08:15:14 ATS0=0 08:15:14 OK 08:15:14 Matched 'OK' 08:15:14 ATD*99***1# 08:15:14 CONNECT 08:15:14 Matched 'CONNECT*' 08:15:15 Connected [09369mV] 08:15:15 001 Initializing Interface: [Connect Init] 08:15:15 Initialise TCP/IP Stack 08:15:15 001 Initializing Interface: [Start PPP] 08:15:15 Connecting 08:15:18 001 Initializing Interface: [PPP Connected] 08:15:18 Connected 10.170.119.223 08:15:18 002 Initializing FTP: [Resolve Server] 08:15:18 DNS Lookup ftp.enviroscanplus.com 08:15:19 002 Initializing FTP: [Connect Server] 08:15:19 Open Connection to ftp.enviroscanplus.com 08:15:21 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 08:15:22 331 User modemtesting@enviroscanplus.com OK. Password required 08:15:22 230 OK. Current restricted directory is / 08:15:23 002 Initializing FTP: [CWD] 08:15:23 250 OK. Current directory is /HL7800 08:15:24 002 Initializing FTP: [SET Binary Mode] 08:15:24 200 TYPE is now 8-bit binary 08:15:25 003 Transferring 08:15:25 004 Uploading to Server 08:15:26 004 Uploading to Server: [Upload File] 08:15:26 227 Entering Passive Mode (198,38,77,48,201,10) 08:15:29 001 Initializing Interface 08:15:40 Disconnect 08:15:44 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&}1-Qã}'}"}(}"ŽI~~ÿ}#À!}%}#} }0User requesty{~ 08:15:44 NO CARRIER 08:15:44 Matched 'NO CARRIER' 08:15:44 AT+CESQ 08:15:44 +CESQ: 99,99,255,255,19,50 08:15:44 OK 08:15:44 Matched 'OK' 08:15:44 AT+CPWROFF 08:15:44 +CEREG: 0 08:15:46 +CEREG: 0 08:15:46 OK 08:15:46 Matched 'OK' 08:15:55 Error timeout 08:15:55 Power down [09371mV]