Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 14488mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-10-18 11:02:00 -- Interval: 2m 0s (1 x 120s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-10-18 10:58:01 10:58:01 Initialize Modem [14555mV] 10:58:09 +CEREG: 2 10:58:09 +KSUP: 0 10:58:10 +CEREG: 0 10:58:10 +CEREG: 2 10:58:13 +CEREG: 5,"8002","08DBCD0B",7 10:58:13 Matched '+CEREG: 5,*' 10:58:13 AT+KPATTERN="SOLAR" 10:58:13 Charger State = 64 [CHARGER_STATE_CC_CV_CHARGE] 10:58:13 Charge Status = 1 [CHARGE_STATUS_CONSTANT_VOLTAGE] 10:58:13 Battery Voltage = 9345mV 10:58:14 Input Voltage = 14875mV 10:58:14 Output Voltage = 14908mV 10:58:14 Battery Current = 1mA 10:58:14 Input Current = 72mA 10:58:14 Die Temp = 267 x10 DegC 10:58:14 Thermistor Voltage = 11259 10:58:14 BSR = 0mOhm 10:58:14 OK 10:58:14 Matched 'OK' 10:58:14 AT+COPS? 10:58:14 +COPS: 0,0,"Hologram",7 10:58:14 OK 10:58:14 Matched 'OK' 10:58:14 AT+CESQ 10:58:14 +CESQ: 99,99,255,255,0,30 10:58:14 OK 10:58:14 Matched 'OK' 10:58:14 AT+KBND? 10:58:14 +KBND: 0,00000000000008000000 10:58:14 OK 10:58:14 Matched 'OK' 10:58:14 Connect [14464mV] 10:58:15 AT+CCLK? 10:58:15 +CCLK: "19/10/18,10:58:12+42" 10:58:15 OK 10:58:15 Matched 'OK' 10:58:15 ATS0=0 10:58:15 OK 10:58:15 Matched 'OK' 10:58:15 ATD*99***1# 10:58:15 CONNECT 10:58:15 Matched 'CONNECT*' 10:58:15 Connected [14403mV] 10:58:15 001 Initializing Interface: [Connect Init] 10:58:15 Initialise TCP/IP Stack 10:58:15 001 Initializing Interface: [Start PPP] 10:58:15 Connecting 10:58:18 001 Initializing Interface: [PPP Connected] 10:58:18 Connected 10.170.119.223 10:58:19 002 Initializing FTP: [Resolve Server] 10:58:19 DNS Lookup ftp.enviroscanplus.com 10:58:20 002 Initializing FTP: [Connect Server] 10:58:20 Open Connection to ftp.enviroscanplus.com 10:58:23 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 10:58:24 331 User modemtesting@enviroscanplus.com OK. Password required 10:58:25 230 OK. Current restricted directory is / 10:58:25 002 Initializing FTP: [CWD] 10:58:25 250 OK. Current directory is /HL7800 10:58:26 002 Initializing FTP: [SET Binary Mode] 10:58:26 200 TYPE is now 8-bit binary 10:58:26 003 Transferring 10:58:27 004 Uploading to Server 10:58:27 004 Uploading to Server: [Upload File] 10:58:27 227 Entering Passive Mode (198,38,77,48,197,2) 10:58:39 001 Initializing Interface 10:58:54 Disconnect 10:58:58 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&p³â)}'}"}(}"}5g~~ÿ}#À!}%}#} }0User requesty{~ 10:58:58 NO CARRIER 10:58:58 Matched 'NO CARRIER' 10:58:58 AT+CESQ 10:58:58 +CESQ: 99,99,255,255,5,30 10:58:58 OK 10:58:58 Matched 'OK' 10:58:58 AT+CPWROFF 10:58:59 +CEREG: 0 10:58:59 +CEREG: 0 10:58:59 OK 10:58:59 Matched 'OK' 10:59:08 Error timeout 10:59:08 Power down [14494mV]