Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 09325mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-10-17 04:00:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-10-17 03:30:02 03:30:02 Initialize Modem [09383mV] 03:30:09 +CEREG: 2 03:30:10 +KSUP: 0 03:30:10 +CEREG: 0 03:30:10 +CEREG: 2 03:30:11 +CEREG: 5,"8003","08D9BF0D",7 03:30:11 Matched '+CEREG: 5,*' 03:30:11 AT+KPATTERN="SOLAR" 03:30:11 Charger State = 256 [CHARGER_STATE_CHARGER_SUSPENDED] 03:30:11 Charge Status = 0 [CHARGE_STATUS_OFF] 03:30:11 Battery Voltage = 9878mV 03:30:12 Input Voltage = 11mV 03:30:12 Output Voltage = 9891mV 03:30:12 Battery Current = -62mA 03:30:12 Input Current = 1mA 03:30:12 Die Temp = 202 x10 DegC 03:30:12 Thermistor Voltage = 12372 03:30:12 BSR = 0mOhm 03:30:12 OK 03:30:12 Matched 'OK' 03:30:12 AT+COPS? 03:30:12 +COPS: 0,0,"Hologram",7 03:30:13 OK 03:30:13 Matched 'OK' 03:30:13 AT+CESQ 03:30:13 +CESQ: 99,99,255,255,18,42 03:30:13 OK 03:30:13 Matched 'OK' 03:30:13 AT+KBND? 03:30:13 +KBND: 0,00000000000008000000 03:30:13 OK 03:30:13 Matched 'OK' 03:30:13 Connect [09339mV] 03:30:14 AT+CCLK? 03:30:14 +CCLK: "19/10/17,03:30:12+42" 03:30:14 OK 03:30:14 Matched 'OK' 03:30:14 ATS0=0 03:30:14 OK 03:30:14 Matched 'OK' 03:30:14 ATD*99***1# 03:30:14 CONNECT 03:30:14 Matched 'CONNECT*' 03:30:14 Connected [09363mV] 03:30:15 001 Initializing Interface: [Connect Init] 03:30:15 Initialise TCP/IP Stack 03:30:15 001 Initializing Interface: [Start PPP] 03:30:15 Connecting 03:30:18 001 Initializing Interface: [PPP Connected] 03:30:18 Connected 10.170.119.223 03:30:18 002 Initializing FTP: [Resolve Server] 03:30:18 DNS Lookup ftp.enviroscanplus.com 03:30:19 002 Initializing FTP: [Connect Server] 03:30:19 Open Connection to ftp.enviroscanplus.com 03:30:21 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 03:30:22 331 User modemtesting@enviroscanplus.com OK. Password required 03:30:23 230 OK. Current restricted directory is / 03:30:23 002 Initializing FTP: [CWD] 03:30:23 250 OK. Current directory is /HL7800 03:30:24 002 Initializing FTP: [SET Binary Mode] 03:30:24 200 TYPE is now 8-bit binary 03:30:25 003 Transferring 03:30:25 004 Uploading to Server 03:30:26 004 Uploading to Server: [Upload File] 03:30:26 227 Entering Passive Mode (198,38,77,48,199,164) 03:30:30 001 Initializing Interface 03:30:43 Disconnect 03:30:48 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&}59ûœ}'}"}(}",S~~ÿ}#À!}%}#} }0User requesty{~ 03:30:48 NO CARRIER 03:30:48 Matched 'NO CARRIER' 03:30:48 AT+CESQ 03:30:48 +CESQ: 99,99,255,255,21,43 03:30:48 OK 03:30:48 Matched 'OK' 03:30:48 AT+CPWROFF 03:30:48 +CEREG: 0 03:30:48 +CEREG: 0 03:30:48 OK 03:30:48 Matched 'OK' 03:30:57 Error timeout 03:30:57 Power down [09316mV]