Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 09351mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-10-17 03:00:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-10-17 02:30:02 02:30:02 Initialize Modem [09426mV] 02:30:09 +KSUP: 0 02:30:10 +CEREG: 2 02:30:10 +CEREG: 0 02:30:10 +CEREG: 2 02:30:11 +CEREG: 5,"8003","08D9BF0D",7 02:30:11 Matched '+CEREG: 5,*' 02:30:12 AT+KPATTERN="SOLAR" 02:30:12 Charger State = 256 [CHARGER_STATE_CHARGER_SUSPENDED] 02:30:12 Charge Status = 0 [CHARGE_STATUS_OFF] 02:30:12 Battery Voltage = 9891mV 02:30:12 Input Voltage = 8mV 02:30:12 Output Voltage = 9906mV 02:30:12 Battery Current = -80mA 02:30:12 Input Current = 1mA 02:30:12 Die Temp = 202 x10 DegC 02:30:12 Thermistor Voltage = 12368 02:30:12 BSR = 0mOhm 02:30:13 OK 02:30:13 Matched 'OK' 02:30:13 AT+COPS? 02:30:13 +COPS: 0,0,"Hologram",7 02:30:13 OK 02:30:13 Matched 'OK' 02:30:13 AT+CESQ 02:30:13 +CESQ: 99,99,255,255,21,43 02:30:13 OK 02:30:13 Matched 'OK' 02:30:13 AT+KBND? 02:30:13 +KBND: 0,00000000000008000000 02:30:14 OK 02:30:14 Matched 'OK' 02:30:14 Connect [09385mV] 02:30:14 AT+CCLK? 02:30:14 +CCLK: "19/10/17,02:30:12+42" 02:30:14 OK 02:30:14 Matched 'OK' 02:30:14 ATS0=0 02:30:14 OK 02:30:14 Matched 'OK' 02:30:15 ATD*99***1# 02:30:15 CONNECT 02:30:15 Matched 'CONNECT*' 02:30:15 Connected [09385mV] 02:30:15 001 Initializing Interface: [Connect Init] 02:30:15 Initialise TCP/IP Stack 02:30:15 001 Initializing Interface: [Start PPP] 02:30:15 Connecting 02:30:18 001 Initializing Interface: [PPP Connected] 02:30:18 Connected 10.170.119.223 02:30:18 002 Initializing FTP: [Resolve Server] 02:30:18 DNS Lookup ftp.enviroscanplus.com 02:30:19 002 Initializing FTP: [Connect Server] 02:30:19 Open Connection to ftp.enviroscanplus.com 02:30:22 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 02:30:23 331 User modemtesting@enviroscanplus.com OK. Password required 02:30:23 230 OK. Current restricted directory is / 02:30:24 002 Initializing FTP: [CWD] 02:30:24 250 OK. Current directory is /HL7800 02:30:25 002 Initializing FTP: [SET Binary Mode] 02:30:25 200 TYPE is now 8-bit binary 02:30:26 003 Transferring 02:30:26 004 Uploading to Server 02:30:27 004 Uploading to Server: [Upload File] 02:30:27 227 Entering Passive Mode (198,38,77,48,202,199) 02:30:31 001 Initializing Interface 02:30:45 Disconnect 02:30:49 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&})}"b§}'}"}(}"¢b~~ÿ}#À!}%}#} }0User requesty{~ 02:30:49 NO CARRIER 02:30:49 Matched 'NO CARRIER' 02:30:49 AT+CESQ 02:30:49 +CESQ: 99,99,255,255,19,42 02:30:49 OK 02:30:49 Matched 'OK' 02:30:49 AT+CPWROFF 02:30:49 +CEREG: 0 02:30:50 +CEREG: 0 02:30:50 OK 02:30:50 Matched 'OK' 02:30:59 Error timeout 02:30:59 Power down [09363mV]