Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 09355mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-10-17 02:30:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-10-17 02:00:02 02:00:02 Initialize Modem [09434mV] 02:00:09 +CEREG: 2 02:00:10 +CEREG: 0 02:00:10 +CEREG: 2 02:00:10 +KSUP: 0 02:00:11 +CEREG: 5,"8003","08D9BF0D",7 02:00:11 Matched '+CEREG: 5,*' 02:00:11 AT+KPATTERN="SOLAR" 02:00:11 Charger State = 256 [CHARGER_STATE_CHARGER_SUSPENDED] 02:00:11 Charge Status = 0 [CHARGE_STATUS_OFF] 02:00:12 Battery Voltage = 9904mV 02:00:12 Input Voltage = 8mV 02:00:12 Output Voltage = 9918mV 02:00:12 Battery Current = -70mA 02:00:12 Input Current = 1mA 02:00:12 Die Temp = 202 x10 DegC 02:00:12 Thermistor Voltage = 12378 02:00:12 BSR = 0mOhm 02:00:12 OK 02:00:12 Matched 'OK' 02:00:12 AT+COPS? 02:00:13 +COPS: 0,0,"Hologram",7 02:00:13 OK 02:00:13 Matched 'OK' 02:00:13 AT+CESQ 02:00:13 +CESQ: 99,99,255,255,14,43 02:00:13 OK 02:00:13 Matched 'OK' 02:00:13 AT+KBND? 02:00:13 +KBND: 0,00000000000008000000 02:00:13 OK 02:00:13 Matched 'OK' 02:00:14 Connect [09373mV] 02:00:14 AT+CCLK? 02:00:14 +CCLK: "19/10/17,02:00:12+42" 02:00:14 OK 02:00:14 Matched 'OK' 02:00:14 ATS0=0 02:00:14 OK 02:00:14 Matched 'OK' 02:00:14 ATD*99***1# 02:00:14 CONNECT 02:00:14 Matched 'CONNECT*' 02:00:15 Connected [09410mV] 02:00:15 001 Initializing Interface: [Connect Init] 02:00:15 Initialise TCP/IP Stack 02:00:15 001 Initializing Interface: [Start PPP] 02:00:15 Connecting 02:00:18 001 Initializing Interface: [PPP Connected] 02:00:18 Connected 10.170.119.223 02:00:18 002 Initializing FTP: [Resolve Server] 02:00:18 DNS Lookup ftp.enviroscanplus.com 02:00:19 002 Initializing FTP: [Connect Server] 02:00:19 Open Connection to ftp.enviroscanplus.com 02:00:21 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 02:00:22 331 User modemtesting@enviroscanplus.com OK. Password required 02:00:23 230 OK. Current restricted directory is / 02:00:24 002 Initializing FTP: [CWD] 02:00:24 250 OK. Current directory is /HL7800 02:00:25 002 Initializing FTP: [SET Binary Mode] 02:00:25 200 TYPE is now 8-bit binary 02:00:25 003 Transferring 02:00:25 004 Uploading to Server 02:00:26 004 Uploading to Server: [Upload File] 02:00:26 227 Entering Passive Mode (198,38,77,48,196,130) 02:00:30 001 Initializing Interface 02:00:48 Disconnect 02:00:52 ~ÿ}#À!}!}"} }4}"}&} } } } }%}&Yfí­}'}"}(}"[ã~~ÿ}#À!}%}#} }0User requesty{~ 02:00:52 NO CARRIER 02:00:52 Matched 'NO CARRIER' 02:00:52 AT+CESQ 02:00:52 +CESQ: 99,99,255,255,17,43 02:00:52 OK 02:00:52 Matched 'OK' 02:00:52 AT+CPWROFF 02:00:52 +CEREG: 0 02:00:52 +CEREG: 0 02:00:53 OK 02:00:53 Matched 'OK' 02:01:02 Error timeout 02:01:02 Power down [09333mV]