Logger ID: SM200_Probe Board ID: XDPI-232 (12/PLUS) Version: 2.1.1 Build: Aug 21 2019 10:54:10 Serial ID: 0004A3FFFE6EF0EE Serial Number: Probe Voltage: 09638mV Sensors: 9 ( Moisture=3 Salinity=3 Temperature=3 ) Next Upload: 19-10-16 17:15:00 -- Interval: 15m 0s (1 x 900s) Dial-In Up Time: Last Response: 040 Success Connection Details: Log started: 19-10-16 16:45:02 16:45:02 Initialize Modem [09638mV] 16:45:09 +CEREG: 2 16:45:10 +KSUP: 0 16:45:10 +CEREG: 0 16:45:10 +CEREG: 2 16:45:11 +CEREG: 5,"8003","08D9BF0D",7 16:45:11 Matched '+CEREG: 5,*' 16:45:11 AT+KPATTERN="SOLAR" 16:45:12 Charger State = 256 [CHARGER_STATE_CHARGER_SUSPENDED] 16:45:12 Charge Status = 0 [CHARGE_STATUS_OFF] 16:45:12 Battery Voltage = 10120mV 16:45:12 Input Voltage = 1606mV 16:45:12 Output Voltage = 10134mV 16:45:12 Battery Current = -90mA 16:45:12 Input Current = 1mA 16:45:12 Die Temp = 272 x10 DegC 16:45:12 Thermistor Voltage = 10838 16:45:12 BSR = 0mOhm 16:45:12 OK 16:45:12 Matched 'OK' 16:45:13 AT+COPS? 16:45:13 +COPS: 0,0,"Hologram",7 16:45:13 OK 16:45:13 Matched 'OK' 16:45:13 AT+CESQ 16:45:13 +CESQ: 99,99,255,255,15,42 16:45:13 OK 16:45:13 Matched 'OK' 16:45:13 AT+KBND? 16:45:13 +KBND: 0,00000000000008000000 16:45:13 OK 16:45:13 Matched 'OK' 16:45:14 Connect [09571mV] 16:45:14 AT+CCLK? 16:45:14 +CCLK: "19/10/16,16:45:14+42" 16:45:14 OK 16:45:14 Matched 'OK' 16:45:14 ATS0=0 16:45:14 OK 16:45:14 Matched 'OK' 16:45:14 ATD*99***1# 16:45:14 CONNECT 16:45:14 Matched 'CONNECT*' 16:45:15 Connected [09588mV] 16:45:15 001 Initializing Interface: [Connect Init] 16:45:15 Initialise TCP/IP Stack 16:45:15 001 Initializing Interface: [Start PPP] 16:45:15 Connecting 16:45:18 001 Initializing Interface: [PPP Connected] 16:45:18 Connected 10.170.119.223 16:45:18 002 Initializing FTP: [Resolve Server] 16:45:18 DNS Lookup ftp.enviroscanplus.com 16:45:19 002 Initializing FTP: [Connect Server] 16:45:19 Open Connection to ftp.enviroscanplus.com 16:45:21 220---------- Welcome to Pure-FTPd [privsep] [TLS] ---------- 16:45:22 331 User modemtesting@enviroscanplus.com OK. Password required 16:45:23 230 OK. Current restricted directory is / 16:45:25 002 Initializing FTP: [CWD] 16:45:25 250 OK. Current directory is /HL7800 16:45:26 002 Initializing FTP: [SET Binary Mode] 16:45:26 200 TYPE is now 8-bit binary 16:45:26 003 Transferring 16:45:26 004 Uploading to Server 16:45:27 004 Uploading to Server: [Upload File] 16:45:27 227 Entering Passive Mode (198,38,77,48,199,69) 16:45:31 001 Initializing Interface 16:45:43 Disconnect 16:45:47 ~}#!}!}"} }4}"}&} } } } }%}&1}'}"}(}"}+~~}#!}%}#} }0User requesty{~ 16:45:47 NO CARRIER 16:45:47 Matched 'NO CARRIER' 16:45:47 AT+CESQ 16:45:47 +CESQ: 99,99,255,255,12,42 16:45:47 OK 16:45:47 Matched 'OK' 16:45:47 AT+CPWROFF 16:45:48 +CEREG: 0 16:45:48 +CEREG: 0 16:45:48 OK 16:45:48 Matched 'OK' 16:45:57 Error timeout 16:45:57 Power down [09628mV]